Chapter 10. JS23 and JS43 power management using EnergyScale technology 403
Figure 10-6 Blade power configuration settings
Power capping is used to allow the user to allocate less power and cooling to a
system. This can help save on datacenter infrastructure costs, and then
potentially allow more servers to be put into an existing infrastructure.
To enable the Power Capping option, use the pull down menu and select Enable.
Then you will be able to set a cap level using the Maximum Power Limit range
box. This value will limit the power usage to the value specified. When the limit
has been reached the blade will be throttled back to limit the consumption to the
maximum value.
Power savings is used to put the server into a mode that consumes less energy.
Power savings can be enabled using one of the various options. Selecting the
Dynamic Power Saver also permits you to select the option to favor performance
over power usage.
Scrolling the page down will allow the user to view trend data for the particular
bladeserver selected. Figure 10-7 on page 404 shows an example of the trend
data.