E-Tech ET8 Especificaciones Pagina 62

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 618
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 61
28 IBM BladeCenter JS23 and JS43 Implementation Guide
provides clients with easy remote management and connectivity to the
BladeCenter H chassis for their critical applications.
BladeCenter H does not ship standard with any I/O modules. You choose these
I/O modules based on your connectivity needs. An Ethernet Switch Module
(ESM) or Passthrough Module will be required in I/O module bays 1 and 2, to
enable the use of both Ethernet ports on a blade server. The I/O modules
required in I/O module bays 3 and 4 depend on the I/O Expansion Card installed
in the blade servers. The I/O modules required in the high-speed I/O module
bays 7, 8, 9, and 10 depend on the HSFF or CFFv I/O Expansion Adapter cards
installed in the blade servers.
The BladeCenter H chassis comes standard with no power cord. Power cords
need to be ordered separately.
The BladeCenter H chassis ships standard with:
򐂰 One advanced management module
򐂰 Two blower modules
򐂰 Two power supply modules (one pair of 2,900-watt power modules).
򐂰 Two hot-swap power supply fan modules
򐂰 Two USB v2.0 ports
򐂰 One DVD-ROM drive
The chassis does not have a diskette drive. An optional USB-attached 1.44 MB
diskette drive is available. The feature code for ordering the external diskette
drive is FC 2591of FRU P/N 03N4962.
Table 2-22 on page 28 provides information on the BladeCenter H (BCH)
specifications.
Table 2-22 BladeCenter H specifications
Feature Specification
Machine type 8852-4XU
Rack dimension 9U x 28 inches (711 mm)
DVD/CD standard drive 1 x DVD ROM (in Media Tray)
Diskette drive None
Number of blade slots 14 (30 mm blade servers)
Number of switch module slots 10 hot-swap (4 x high speed, 4 x standard, 2 x
bridge)
Vista de pagina 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 617 618

Comentarios a estos manuales

Sin comentarios