16
PROGRAMMING
E-TECH ET8 (V4) CONTROL PANEL INSTALLER MANUAL
VIBRATION SENSITIVITY
Each zone has individually adjustable sensitivity for connection of E-Techensor
Vibration Sensors.
Zone sensitivity is adjusted by toggling zones ON in options P30E to P38E.
P30E, Normal Sensitivity vibration analyser disabled. This is used for normal
alarm devices. Zone response time, 200ms.
P3138E are the options for the 8 levels of vibration sensitivities. P31E is the
most sensitive setting.
PROGRAMMING SEQUENCE:
P [3038] E zones are displayed [Zone No] E
EXAMPLE: To program zones 2 and 3 to be Medium Sensitivity:
P34E 2E 3E the keypad display will show zone lights 2 & 3 to be ON
P30E P38E
PROGRAM MODE LEVEL:
Installer, Remote by PC
FACTORY DEFAULT:
Normal sensitivity.
P30E, all zones = ON
NOTES:
Sensitivity can be individually
programmed for each zone.
Zones are allocated to one sensitivity level
at any one time. Turning a zone ON in a
sensitivity level, turns the zone OFF in any
other sensitivity level.
To revert zone sensitivity back to Normal.
Turn the required zone/s ON at Option 30.
Avoid using P31 and P38 sensitivity
they are provided as a guide to the upper
and lower limits.
USING E-TECHSENSORS.
E-Techsensors are sensitive to high fre-
quencies and insensitive to low frequen-
cies. Therefore it is not necessary to apply
much force to the protected structure,
rather a very rapid succession of blows.
The sensitivity has been correctly ad-
justed when a single blow applied with a
soft object (e.g. by hand) does not cause
an alarm whereas a rapid series of blows
(using a metal object such as a screw-
driver blade) will cause an alarm.
32
M
H
LL
RED
YELLOW
N/C Vibration
contacts
N/C Tamper
loop
BLUE
GREEN
36mm
51mm
20mm
16.5mm
350mm cable
2 x
at 27mm spacing
3mm holes
E-Tech E-TECHSENSOR Vibration
sensor
Part No. VIB100
In addition to zone sensitivity adjustment,
the overall sensitivity of the E-
Techsensor can be adjusted by rotating
the body of the E-Techsensor within its
bracket.
The bracket must always be mounted
horizontally and the arrow must
point up for any required setting.
VIBRATION SENSITIVITY
Example P34E: Zones 2 & 3 are
Medium sensitivity.
41326578
Factory Default Setting for P30E.
All zones selected ON = Normal
sensitivity.
OPTION No SENSITIVITY 1 2 3 4 5 6 7 8
Zones
ON = Factory default setting
P30E
Normal
P31E High
P32E
P33E
P34E
P35E
P36E
P37E
P38E Low
ON ON ON ON ON ON ON ON